required, a separate paragraph for each type will be
used. Each type will be designated with a letter or
number symbol. Use the same symbols to key flooring
to locations on the drawings and in Section 09915
COLOR SCHEDULE. Delete reference to type symbol if
not used.
**************************************************************************
2.1
**************************************************************************
tile (VCT) should be utilized in high traffic
commercial type installations. The 2.4 mm
(3/32-inch) thick VCT should be considered for light
to medium duty areas such as rooms in BEQ's and
BOQ's.
Solid color tiles are tiles with uniform color
throughout. These are recommended for use as an
accent only in small quantities and not as the floor
field color. These tiles do not hide soiling well
and show scratches easily.
Through pattern tiles are tiles with patterning
distributed through the entire thickness.
**************************************************************************
Vinyl-composition tile shall conform to ASTM F 1066, [Class 1, (solid color
tile),][Class 2, (through pattern tile),] Composition 1, asbestos-free, and
shall be [300] [_____] mm [12] [_____] inches square and [2.4] [3.2] mm
[3/32] [1/8] inch thick. Tile shall have the color and pattern uniformly
distributed throughout the thickness of the tile.
2.2
SHEET VINYL FLOORING [TYPE [A] [_____]]
**************************************************************************
NOTE: Not all sheet vinyl flooring is available
with chemically bonded and/or heat welded seams.
Research available products and coordinate with
facility requirements.
**************************************************************************
Sheet vinyl flooring shall conform to [ASTM F 1303, Type I, Grade 1, [Class
A-non-asbestos formulated fibrous backing] [or] [Class B-nonfoamed plastic
backing] (minimum wear layer thickness 0.5 mm 0.020 inches and minimum
overall thickness 2 mm 0.080 inches) and shall not be less than [1800 mm 6
feet] [3660 mm 12 feet] wide.] [ASTM F 1303, Type II, Grade 1, without
backing (minimum wear layer thickness 2 mm 0.080 inches and minimum overall
thickness 2 mm 0.080 inches), and shall be not less than 1800 mm 6 feet
wide. Color and pattern shall extend through the total thickness of the
material.] [ASTM F 1303, Type II, Grade 1, [Class A non-asbestos formulated
fibrous backing] [or] [Class B nonfoamed plastic backing] (minimum wear
layer thickness 1.27 mm 0.050 inches and minimum overall thickness 2 mm
0.080 inches) and shall be not less than 1800 mm 6 feet wide. Color and
pattern shall extend throughout the thickness of the wearlayer.] [ASTM F
1913, (minimum wear layer thickness 1.9 mm 0.075 inches and minimum overall
thickness 1.9 mm 0.075 inches) and shall be not less than 1800 mm 6 feet
wide. Color and pattern shall extend through the total thickness of the
SECTION 09650
Page 9