Resilient Flooring and Accessories[; G][; G, [_____]]
[Three] [_____] samples of each indicated color and type of
flooring, base, mouldings, and accessories. Sample size shall be
minimum 60 x 100 mm 2-1/2 x 4 inches.
SD-06 Test Reports
Moisture, Alkalinity and Bond Tests[; G][; G, [_____]]
Copy of test reports of moisture and alkalinity content of
concrete slab, and bond test stating date of test, person
conducting the test, and the area tested.
SD-08 Manufacturer's Instructions
Surface Preparation[; G][; G, [_____]]
Installation[; G][; G, [_____]]
flooring materials and accessories, including preparation of
substrate, seaming techniques, and recommended adhesives.
SD-10 Operation and Maintenance Data
Resilient Flooring and Accessories[; G][; G, [_____]]
Data Package 1 in accordance with Section 01781 OPERATION AND
MAINTENANCE DATA.
1.4
DELIVERY AND STORAGE
Materials shall be delivered to the building site in original unopened
containers bearing the manufacturer's name, style name, pattern color name
and number, production run, project identification, and handling
instructions. Materials shall be stored in a clean dry area with
temperature maintained above 20 degrees C 68 degrees F and below 30 degrees
C 85 degrees F, and shall be stacked according to manufacturer's
recommendations. Materials shall be protected from the direct flow of heat
from hot-air registers, radiators and other heating fixtures and
appliances. Do not open containers until materials are to be used, except
for verification inspection. Observe ventilation and safety procedures
specified in the MSDS.
1.5
ENVIRONMENTAL REQUIREMENTS
Areas to receive resilient flooring shall be maintained at a temperature
above 20 degrees C 68 degrees F and below 30 degrees C 85 degrees F for 2
days before application, during application and 2 days after application,
unless otherwise directed by the flooring manufacturer for the flooring
being installed. A minimum temperature of 13 degrees C 55 degrees F shall
be maintained thereafter. Observe ventilation and safety procedures
specified in the MSDS. Provide adequate ventilation to remove moisture
from area and to comply with regulations limiting concentrations of
hazardous vapors.
SECTION 09650
Page 7