1.5.5
Format of SD-04 Samples
a.
Furnish samples in sizes below, unless otherwise specified or
unless the manufacturer has prepackaged samples of approximately
same size as specified:
(1)
Sample of Equipment or Device:
Full size.
(2) Sample of Materials Less Than 50 by 75 mm 2 by 3 inches:
Built up to A4 (297 by 210 mm) 8 1/2 by 11 inches.
(3) Sample of Materials Exceeding A4 (297 by 210 mm) 8 1/2 by 11
inches: Cut down to A4 (297 by 210 mm) 8 1/2 by 11 inches and
adequate to indicate color, texture, and material variations.
(4) Sample of Linear Devices or Materials: 250 mm 10 inch length
or length to be supplied, if less than 250 mm 10 inches. Examples
of linear devices or materials are conduit and handrails.
(5) Sample of Non-Solid Materials: 750 ml Pint.
Examples of
non-solid materials are sand and paint.
(6)
Color Selection Samples:
50 by 100 mm 2 by 4 inches.
(7)
Sample Panel:
1200 by 1200 mm 4 by 4 feet.
(8)
Sample Installation:
10 square meters 100 square feet.
b.
Samples Showing Range of Variation: Where variations are
unavoidable due to nature of the materials, submit sets of samples
of not less than three units showing extremes and middle of range.
c.
Reusable Samples: Incorporate returned samples into work only if
so specified or indicated. Incorporated samples shall be in
undamaged condition at time of use.
d.
Recording of Sample Installation: Note and preserve the notation
of area constituting sample installation but remove notation at
final clean up of project.
**************************************************************************
NOTE: To avoid unnecessary effort by the
Contractor, use the following paragraph only when
there is no color board prepared during design.
**************************************************************************
e.
When color, texture or pattern is specified by naming a particular
manufacturer and style, include one sample of that manufacturer
and style, for comparison.
1.5.6
Format of SD-05 Design Data and SD-07 Certificates
a.
Provide design data and certificates on 297 by 210 mm 8 1/2 by 11
inches paper. Provide a bound volume for submittals containing
numerous pages.
1.5.7
Format of SD-06 Test Reports and SD-09 Manufacturer's Field Reports
a.
Provide reports on 297 by 210 mm 8 1/2 by 11 inches paper in a
SECTION 01330