loaded component per panel per side. Panels shall be either tackable or
capable of accommodating fabric covered tackboards. The panel system shall
be available in a variety of nominal widths and heights as designated on
the drawings. Heights shall be measured from the finished floor to the top
of the panel. Powered and nonpowered panels shall be compatible in
height. Panel heights shall be coordinated with the HVAC and electrical
designs. The Contractor shall submit Assembly Manuals as specified in the
Submittals paragraph.
2.2.2
Stacking Panel-Frame System
Accessories and appurtenances for a completely finished panel assembly
shall be supplied complete with the system. The system shall be capable of
structurally supporting cantilevered work surfaces, shelves, files, and
other components in the configurations shown on the drawings. The panel
system shall be capable of structurally supporting more than 1 fully loaded
component per panel per side. Panels shall be either tackable or capable
of accommodating fabric covered tackboards. The system shall be capable of
lowering or raising the overall panel assembly height, at horizontal
connections, by either removing or adding panel-frames on-site without
disturbing adjacent panel components. The panel system shall be available
in a variety of nominal widths and heights as designated on the drawings
and shall be vertically stackable. Heights shall be measured from the
finished floor to the top of the panel assembly. Panel heights shall be
coordinated with the HVAC and electrical designs.
2.2.3
Spine Wall System
Accessories and appurtenances for a completely finished spine wall assembly
shall be supplied complete with the system. The wall system shall be
capable of structurally supporting cantilevered work surfaces, shelves,
files, and other components in the configurations shown on the drawings, as
well as allow various off module attachment locations horizontally for
these components. The spine wall system shall be capable of structurally
supporting more than one fully loaded component per panel per side. It
shall be available in a variety of nominal widths and heights as designated
on the drawings. [Wall height may be lowered or raised at horizontal
connections by either removing or adding wall tiles on-site without
disturbing adjacent wall components.] Heights shall be measured from the
finished floor to the top of the panel. Wall heights shall be coordinated
with the HVAC and electrical designs. Electrical and data management will
be easily accessible by removable wall covers which can be removed while
workstation components are still attached. Cables shall be laid in the
system, not threaded through the frame.
2.2.4
Desk-Based Systems
Accessories and appurtenances for a completely finished desk-based assembly
shall be supplied complete with the system. The desk-based system shall be
free-standing and independent of panel system support. It shall be capable
of structurally supporting work surfaces, shelves, and other components in
the configurations shown on the drawings. The system shall be available in
a variety of nominal widths as defined on drawings.
2.2.5
**************************************************************************
NOTE: Specify a finish and fabric for applicable
items. Include fabric content, ex: 50% Nylon, 50%
SECTION 12705
Page 13