1.6.2
Component Requirements
The types of components or elements utilized shall be as shown on the
drawings and as specified in PART 2 PRODUCTS of this specification.
1.6.3
Layout
The storage capacity, number of workstations accommodated, width of aisles,
or workstation configuration shall not be reduced.
1.6.4
Wiring Configuration
Alternate configurations must support the circuiting and connection
capabilities identified under the provisions pertaining to power
distribution of paragraph ELECTRICAL. Generally any alternate will be
acceptable which involves only a variation in size or quantity that exceeds
the specified configuration.
1.7
WARRANTY
The Contractor shall warrant the furniture systems for a period of 10 years
with the following exceptions: fabrics and other covering materials, and
paper handling products shall be guaranteed for 3 years, and task lights
shall be warranted for 2 years. [Electromagnetic ballasts shall be
warranted for 2 years.] [Electronic ballasts shall be warranted for 3
years.] [The electronic ballast warranty shall include a labor
allowance for each ballast.] Warranties shall be signed by the authorized
representative of the manufacturer. Warranties accompanied by document
authenticating the signer as an authorized representative of the guarantor,
shall be presented to the Contracting Officer upon the completion of the
project. The Contractor shall guarantee that the workstation products and
installation are free from any defects in material and workmanship from the
date of delivery.
PART 2
PRODUCTS
**************************************************************************
NOTE: The designer must ascertain that the
combination of products specified are not
proprietary and that they can be provided by several
manufacturers. The workstation layout shall
conform to NFPA 101, and for buildings not excluded
by TI 800-01 Design Criteria shall be accessible in
accordance with 36 CFR 1191. Considerations for
height adjustable work surfaces and storage design
shall be made when ADA conformance within the
workstation is required. The use of existing
reconditioned furniture systems shall be considered
when appropriate.
**************************************************************************
2.1
PERFORMANCE AND SAFETY REQUIREMENTS
Recyclable materials shall conform to EPA requirements in accordance with
Section 01670 RECYCLED / RECOVERED MATERIALS. Panels, spine walls, frames
and frame covers, connection system, work surfaces, pedestals, shelf units,
flipper door units, lateral files, locks, accessories, and miscellaneous
hardware shall meet testing as specified. ISO 9001 certified manufacturers
SECTION 12705