1.3.2
Drawings showing communications, electronic data processing (EDP) and local
area network (LAN) locations may be provided as a separate submittal from
remaining workstation drawings. Drawing requirements, which are the
furniture manufacturer's responsibility, shall be provided as a single
submittal. Electronic drawings shall be provided to the user for future
re-configuration in the software package requested by the user. The
electronic drawings shall include all modifications made during
installation. As a minimum, the Contractor shall submit the following:
a. Overall reference drawings: Drawings showing workstation
locations and overall plan view within each floor. The scale
shall be [1:400 (1/16 inch = 1 foot) 1/16 inch = 1 foot] [1:200
(1/8 inch = 1 foot) 1/8 inch = 1 foot]. Layouts shall reflect
field verified conditions.
b. Installation drawings: Drawings showing workstations,
panels, spine walls, components, and plan view within each floor.
Workstations shall be identified by workstation type. Scale of
drawings shall be identical to Architectural plans. Installation
drawings shall reflect field verified conditions.
c. Workstation elevations: Dimensioned workstation elevations
showing each type of workstation with panel frame [and spine wall
frame] configurations and all components identified with
manufacturer's catalog numbers. Elevations shall be drawn at 1:50
(1/2 inch = 1 foot) 1/2 inch = 1 foot scale.
d. Panel drawings: Panel [and Spine Wall] drawings showing
finished face of walls, columns, panels, including clearances and
aisle widths. Assemblies shall be keyed to a legend which shall
include width, height, configuration and composition of frame
covers finishes and fabrics (if different selections exist within
a project), power or nonpower, connectors and wall mount hardware.
Drawings shall reflect field verified conditions.
e. Electrical drawings: Drawings showing power provisions
including type and location of feeder components (service entry
poles, base or ceiling feeds), activated outlets and other
electrical components. Wiring configuration (circuiting,
switching, internal and external connections) shall be identified
and a legend provided as applicable.
f.
Wire management capacity drawings.
g. Communication drawings showing telephone provisions:
Drawings indicating the type and location of feeder components and
outlets with wiring configuration identified where applicable.
h. Communication drawings showing electronic data processing
provisions: Drawings indicating the type and location of feeder
components, outlets, or accessories with wiring configuration
identified where applicable.
i. Communication drawings showing local area network
provisions: Drawings indicating the type and location of feeder
components and data outlets with extra ports for future expansion
SECTION 12705