DIVISION 4: INTERIOR CONCRETE MASONRY UNITS PAINT TABLE
System DFT: 4.5 mils 112 microns]
[MPI RIN 4.2C-G5 (Semigloss)
Spot Primer:
Intermediate:
Topcoat:
MPI 50
MPI 47
MPI 47
System DFT: 4.5 mils 112 microns]
[MPI RIN 4.2C-G6 (Gloss)
Spot Primer:
Intermediate:
Topcoat:
MPI 50
MPI 48
MPI 48
System DFT: 4.5 mils 112 microns]]
3. [Epoxy
MPI RIN 4.2D-G6 (Gloss)
Spot Primer:
Intermediate:
Topcoat:
MPI 77
MPI 77
MPI 77
System DFT: 5 mils 125 microns]
**************************************************************************
NOTE: (DIVISION 5: INTERIOR METAL, FERROUS AND
NON-FERROUS PAINT TABLE)
(Substrate C). List other high humidity areas
requiring enamel finishes. For tile-like finishes,
filler materials, and applications, refer to Section
09963 HIGH-BUILD GLAZE COATING. These high
performance coatings are normally used to meet
exposure-resistant requirements and can be applied
to wood, metal, and concrete substrates.
**************************************************************************
**************************************************************************
NOTE: (DIVISION 5: INTERIOR METAL, FERROUS AND
NON-FERROUS PAINT TABLE)
(Substrate F, G, and H). Heat Resistant Paints may
require a high heat cure cycle to achieve proper
cure. Curing requirements should be determined
before specifying so that the supplier will be aware
of requirements.
(Substrate F and G). Consider hot dip galvanizing,
aluminum metallizing, and zinc metallizing
alternatives to the specified coating systems.
(Substrate H). Consider aluminum metallizing
alternative to the specified coating system.
**************************************************************************
DIVISION 5:
INTERIOR METAL, FERROUS AND NON-FERROUS PAINT TABLE
INTERIOR STEEL / FERROUS SURFACES
A.
Metal, [Mechanical,] [Electrical,] [Fire extinguishing sprinkler systems
including valves, conduit, hangers, supports,][Surfaces adjacent to
painted surfaces (Match surrounding finish),] [exposed copper piping,] [and
SECTION 09900
Page 62