DIVISION 4: INTERIOR CONCRETE MASONRY UNITS PAINT TABLE
1. [High Performance Architectural Latex
[MPI RIN 4.2K-G2 (Flat)
Spot Primer:
Intermediate:
Topcoat:
MPI 50
MPI 138
MPI 138
System DFT: 4.5 mils 112 microns]
[MPI RIN 4.2K-G3 (Eggshell)
Spot Primer:
Intermediate:
Topcoat:
MPI 50
MPI 139
MPI 139
System DFT: 4.5 mils 112 microns]
[MPI RIN 4.2K-G4
Spot Primer:
Intermediate:
Topcoat:
MPI 50
MPI 140
MPI 140
System DFT: 4.5 mils 112 microns]
[MPI RIN 4.2K-G5 (Semigloss)
Spot Primer:
Intermediate:
Topcoat:
MPI 50
MPI 141
MPI 141
System DFT: 4.5 mils 112 microns]]
2. [Institutional Low Odor / Low VOC Latex
[Existing; MPI RIN 4.2L-G2 (Flat)
Spot Primer:
Intermediate:
Topcoat:
MPI 50
MPI 144
MPI 144
System DFT: 4 mils 100 microns]
[Existing; MPI RIN 4.2L-G3 (Eggshell)
Spot Primer:
Intermediate:
Topcoat:
MPI 50
MPI 145
MPI 145
System DFT: 4 mils 100 microns]
[Existing; MPI RIN 4.2L-G4 (Satin)
Spot Primer:
Intermediate:
Topcoat:
MPI 50
MPI 146
MPI 146
System DFT: 4 mils 100 microns]
[Existing; MPI RIN 4.2L-G5 (Semigloss)
Spot Primer:
Intermediate:
Topcoat:
MPI 50
MPI 147
MPI 147
System DFT: 4 mils 100 microns]]
C.
New [and uncoated Existing] Concrete masonry units in [toilets],
[food-preparation], [food-serving], [restrooms], [laundry areas], [shower
areas], [areas requiring a high degree of sanitation], [
], [and
other high humidity areas] unless otherwise specified:
1. [Waterborne Light Industrial Coating
[MPI INT 4.2K-G3(Eggshell)
Filler:
Primer:
Intermediate:
Topcoat:
MPI 4
N/A
MPI 110-G3
MPI 110-G3
System DFT: 11 mils 275 microns]
[MPI INT 4.2K-G5(Semigloss)
Filler:
Primer:
Intermediate:
Topcoat:
MPI 4
N/A
MPI 110-G5
MPI 110-G5
System DFT: 11 mils 275 microns]
SECTION 09900
Page 60