INTERIOR STEEL / FERROUS SURFACES
System DFT: 5 mils 125 microns]
[MPI INT 5.4F-G4 (Satin)
Primer:
Intermediate:
Topcoat:
MPI 95
MPI 140
MPI 140
System DFT: 5 mils 125 microns]
[MPI INT 5.4F-G5 (Semigloss)
Primer:
Intermediate:
Topcoat:
MPI 95
MPI 141
MPI 141
System DFT: 5 mils 125 microns]]
2.
[Alkyd
[MPI INT 5.4J-G2 (Flat)
Primer:
Intermediate:
Topcoat:
MPI 95
MPI 49
MPI 49
System DFT: 5 mils 125 microns]
[MPI INT 5.4J-G3 (Eggshell)
Primer:
Intermediate:
Topcoat:
MPI 95
MPI 51
MPI 51
System DFT: 5 mils 125 microns]
[MPI INT 5.4J-G5 (Semigloss)
Primer:
Intermediate:
Topcoat:
MPI 95
MPI 47
MPI 47
System DFT: 5 mils 125 microns]
[MPI INT 5.4J-G6 (Gloss)
Primer:
Intermediate:
Topcoat:
MPI 95
MPI 48
MPI 48
System DFT: 5 mils 125 microns]]
F.
Hot metal surfaces [including smokestacks] subject to temperatures up to
205 degrees C (400 degrees F):
1. [Heat Resistant Enamel
MPI INT 5.2A
Primer:
Intermediate:
Topcoat:
MPI 21
Surface preparation and number of coats per
manufacturer's instructions.
System DFT: Per Manufacturer]
G.
Ferrous metal subject to high temperature, up to 400 degrees C (750
degrees F):
1. [Inorganic Zinc Rich Coating
MPI INT 5.2C
Primer:
Intermediate:
Topcoat:
MPI 19
Surface preparation and number of coats per
manufacturer's instructions.
System DFT: Per Manufacturer]
2. [Heat Resistant Aluminum Paint
MPI INT 5.2B (Aluminum Finish)
Primer:
Intermediate:
Topcoat:
MPI 2
Surface preparation and number of coats per
SECTION 09900