transport to a scrap metal collection or recycle facility.]
3.1.10
Carpentry
Salvage and recycle lumber, millwork items, and finished boards except
those that are unfit for reuse. Remove windows, doors and frames and
similar items as whole units, complete with trim and accessories. Do not
remove hardware attached to units, except for door closers. Brace the open
end of door frames to prevent damage.
3.1.11
Airfield Lighting
Remove existing airfield lighting as indicated and terminate in a manner
satisfactory to the Contracting Officer. Remove [edge lights], [associated
transformers] [and] [_____] as indicated and [deliver to a location on the
station in accordance with instructions of the Contracting Officer].
[dispose of off station]. [_____].
3.1.12
Patching
Where removals leave holes and damaged surfaces exposed in the finished
work, patch and repair these holes and damaged surfaces to match adjacent
finished surfaces. Where new work is to be applied to existing surfaces,
perform removals and patching in a manner to produce surfaces suitable for
receiving new work. Finished surfaces of patched area shall be flush with
the adjacent existing surface and shall match the existing adjacent surface
as closely as possible as to texture and finish. Patching shall be as
specified and indicated, and shall include:
a.
Concrete and Masonry: Completely fill holes and depressions,
[caused by previous physical damage or] left as a result of
removals in existing masonry walls to remain, with an approved
masonry patching material, applied in accordance with the
manufacturer's printed instructions.
b.
Where existing partitions have been removed leaving damaged or
missing resilient tile flooring, patch to match the existing floor
tile.
c.
Patch acoustic lay-in ceiling where partitions have been removed.
The transition between the different ceiling heights shall be
effected by continuing the higher ceiling level over to the first
runner on the lower ceiling and closing the vertical opening with
a painted sheet metal strip.
3.1.13
**************************************************************************
NOTE: Delete requirements if inapplicable.
NOTE: Quantify by weight the amount and type of
refrigerant to be recovered and indicate on plans.
NOTE: Directives from the Secretary of the Navy
prohibit sale or transfer of Class I ODS materials
outside of the Navy without prior approval from the
Chief of Naval Operations or the Commandant of the
Marine Corps.
**************************************************************************
SECTION 02220
Page 15