PART 2
PRODUCTS
2.1
PASSENGER ELEVATORS
2.1.1
Basic Requirements
**************************************************************************
NOTE: Provide all elevators of size to accommodate
handicapped access as a minimum. For all buildings
of four stories or more in height, provide at least
one elevator of size to accommodate emergency
medical services.
For car door opening of passenger and service
elevators, 1065 mm (3 ft. 6 in.) is standard, except
with 1800 kg (4000 lb.) passenger cars, use 1200 mm
(4 ft. 0 in). For special purposes, 1525 mm (5 ft.
0 in.) opening may be used.
Use two speed center opening option restrictively
for elevators where larger door opening is needed
and hoistway space is not available for
single-speed. Otherwise, use single-speed side
slide, single-speed center opening, or two-speed
side slide.
**************************************************************************
a.
Rated Load: [_____] kg lbs.
b.
Rated Speed: [_____] mps fpm
c.
Travel Length: [_____] m ft.
d.
Number of Stops: [_____]
e.
Number of Hoist Way Openings: [_____] Front; [_____] Rear
[_____] mm high [_____] ft.-in. wide, [_____] ft.-in. deep and
[_____] ft.-in. high
g. Car Door Opening: [_____] mm wide and [_____] mm high [_____]
ft.-in. wide and [_____] ft.-in. high
h. Car Door Types: [Single-speed side slide] [Single-speed center
opening] [Two-speed side slide] [Two-speed center opening]
Horizontal sliding.
2.1.2
**************************************************************************
NOTE: Indicate finish colors of elevator materials
in finish schedule on drawings.
Use stainless steel door facing and side panels and
wall trim in hospital cars and for moist
environments such as humid or moist areas such as
hydroelectric plants, locks, and dams.
**************************************************************************
SECTION 14240
Page 13