b.
Condition THREE (Sustained winds of 93 km/hr 50 knots or greater
expected within 48 hours): Maintain "Condition FOUR" requirements
and commence securing operations necessary for "Condition ONE"
which cannot be completed within 18 hours. Cease all routine
activities which might interfere with securing operations.
preparations for securing buildings. Review requirements
pertaining to "Condition TWO" and continue action as necessary to
attain "Condition THREE" readiness. Contact Contracting Officer
for weather and COR updates and completion of required actions.
c.
Condition TWO (Sustained winds of 93 km/hr 50 knots or greater
expected within 24 hours): Curtail or cease routine activities
until securing operation is complete. Reinforce or remove form
work and scaffolding. Secure machinery, tools, equipment,
materials, or remove from the jobsite. Expend every effort to
clear all missile hazards and loose equipment from general base
areas. Contact Contracting Officer for weather and Condition of
Readiness (COR) updates and completion of required actions.
d.
Condition ONE. (Sustained winds of 93 km/hr 50 knots or greater
expected within 12 hours): Secure the jobsite, and leave
Government premises.
][1.8
STATION OPERATION AFFECT ON CONTRACTOR OPERATIONS
**************************************************************************
NOTE: Use this paragraph on all projects involving
potential conflicts with operating conditions other
than utilities or where the work must be pursued in
a particular sequence. Clearly detail the
permissible extent of sequencing or duration of
interruptions to station operation. Obtain
information from the Government.
**************************************************************************
[_____]
[1.8.1
Restricted Access Areas
The Government will monitor work in areas [listed below] [indicated].
Notify Contracting Officer at least 14 calendar days prior to starting work
in these areas.
[_____]
][1.8.2
Special Restrictions Regarding Access of Vehicles and Parking
**************************************************************************
NOTE: Do not add information related to station
regulations which are of a routine nature. Unusual
access provisions dictated by the needs of a
particular project may be included, as directed.
**************************************************************************
[_____].
SECTION 01500N