for base paint standards.
**************************************************************************
[Paint in accordance with base standards] [Suitably paint] and maintain the
temporary facilities. Failure to do so will be sufficient reason to
require their removal.
][1.11.2
Navy Construction Representative's Office
**************************************************************************
NOTE: For locations remote from a ROICC office.
This provision will be deleted at most stations and
for most projects. For specific direction, contact
the EFD/EFA Construction Division.
**************************************************************************
Provide an office with a minimum of [9] [18] [_____] square meter [100]
[200] [_____] square feet of useful floor area for the exclusive use of
Government personnel, in addition to and separate from any other office
space provided by the Contractor. Provide a weathertight structure with
adequate [heating and cooling,] toilet facilities, lighting, ventilation, a
1200 by 2400 mm 4 by 8 foot plan table, [computer work space] a standard
size office desk and chair, and telephone. [Provide either a 1,500 watt
radiant heater and a window-mounted air conditioner rated at [1.3] [2.6] kW
[4,500] [9,000] Btus minimum or a window-mounted heat pump of the same
minimum heating and cooling ratings.] [Include the utilities required to
make these items operable.] Provide a door with a cylinder lock and windows
with locking hardware. Make utility connections. Locate [as directed]
[where indicated]. After completion of the work, remove the entire
structure from the site.
][1.11.3
Quality Control Manager Records and Field Office
**************************************************************************
NOTE: Include this paragraph when project has
separate QC Manager and project Superintendent.
Edit to suit the size and location of the project.
**************************************************************************
Provide on the jobsite an office with approximately [9] [18] [_____] square
meter [100] [200] [_____] square feet of useful floor area for the
exclusive use of the QC Manager. Provide a weathertight structure with
adequate [heating and cooling,] toilet facilities, lighting, ventilation, a
1200 by 2400 mm 4 by 8 foot plan table, a standard size office desk and
chair, computer station, and working communications facilities. [Provide
either a 1,500 watt radiant heater and a window-mounted air conditioner
rated at 2.6 kW 9,000 Btus minimum or a window-mounted heat pump of the
same minimum heating and cooling ratings.] Provide a door with a cylinder
lock and windows with locking hardware. Make utility connections. Locate
[as directed] [where indicated]. File quality control records in the
office and make available at all times to the Government. After completion
of the work, remove the entire structure from the site.
]1.11.4
Trailers or Storage Buildings
**************************************************************************
NOTE: Use this paragraph for projects located on
the Naval Base Complex, Norfolk, Virginia.
**************************************************************************