provided at no additional cost to the Government.
1.4.1.4
Current State-Of-The-Art Technology
The NCAV System application design and products shall utilize current
state-of-the-art computer, networking, and communications technology to
provide the enhanced capability and performance specified herein.
1.4.1.5
Continuous Duty Design
All equipment shall be designed for 24 hours per day, 365 days per year
continuous 100 percent duty operation.
1.4.1.6
worst-case condition of system operation and signaling that could occur in
the application environment without any loss or perceptible degradation of
supplies for worst-case conditions, and this calculation shall be included
with the design data submittal.
b. AC powered equipment shall operate per specifications over the range of
105V to 130V, 60 Hz, unless otherwise noted.
c. All equipment connected to ac power circuits shall be protected from
power line transients and surges as likely to be subjected in service from
a commercial utility ac power system. Protection shall be integral to the
equipment or installed as an accessory item in accordance with
Manufacturer's recommendations. Fuses shall not be used for this
protection.
d. Power distributed over system cables shall be low voltage and power
limited in accordance with NFPA 70 and UL 1069.
1.4.1.7
Shielding and Grounding
All products shall be shielded and grounded as required by the system
design, Manufacturer's instructions, UL 1069 listing, and regulatory
requirements.
1.4.1.8
Station Connectors
All stations shall plug into system cabling.
Stations hardwired to system
cabling are not acceptable.
1.4.1.9
User Room Numbers and Names
Architectural room numbers and names indicated on the contract documents
may be used for the initial system application design and installation
work. However, in the final system application design, medical facility
user room numbers and names that have been designated by the Contracting
Officer shall be used for all system functions and as-built documentation.
a. In medical facilities that have multi-bed patient bedrooms, the user
room number shall also identify each bed in the bedroom.
b. User room numbers and names shall be consistent with the room numbers
and names used in the medical facility information system ADT program, and
SECTION 16731A
Page 14