submittal is sufficiently important or complex in
context of the project.
For submittals requiring Government approval on Army
projects, a code of up to three characters within
the submittal tags may be used following the "G"
designation to indicate the approving authority.
Codes for Army projects using the Resident
Management System (RMS) are: "AE" for
Architect-Engineer; "DO" for District Office
(Engineering Division or other organization in the
District Office); "AO" for Area Office; "RO" for
Resident Office; and "PO" for Project Office. Codes
following the "G" typically are not used for Navy
projects.
Submittal items not designated with a "G" are
considered as being for information only for Army
projects and for Contractor Quality Control approval
for Navy projects.
**************************************************************************
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are [for Contractor Quality Control
approval.][for information only. When used, a designation following the
"G" designation identifies the office that will review the submittal for
the Government.] The following shall be submitted in accordance with
Section 01330 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
[
Crane track fittings; G]
[
Switch throw mechanisms and housings; G]
[
[
Weldable, adjustable rail clips; G]
[
Do not prepare drawings before the completion of field survey
and measurements. Submit details for [casting] [and]
[fabrication] of fittings. Include complete dimensioning,
alignment data, shop instructions, and a material list indicating
description and quantity of components and fasteners for each
fitting. Submit drawings for each individual fitting which is
adequate to determine the conformance of fittings with project
drawings and as provided for herein. Show details of drainage
connections from fittings and housings to drain pipes. Do not
manufacture materials until drawings have been approved.
SD-03 Product Data
Rail materials; G
joint bars and methods of installation; G
SECTION 14606N
Page 7