adjacent unsealed areas to have asbestos fiber concentrations in excess of
0.01 fibers per cubic centimeter or background whichever is higher. In no
circumstance shall levels exceed 0.1 fibers per cubic centimeter.
1.5.6
Pressure Differential Recordings for Local Exhaust System
**************************************************************************
NOTE: When an negative pressure enclosure is not
required, delete the requirements for the local
exhaust system and pressure differential recording.
**************************************************************************
**************************************************************************
NOTE: Normal practice is to have the Contractor
hire one independent Private Qualified Person (the
PQP) to perform all required functions. However,
some applicable laws forbid this approach and will
dictate when the PQP, the NC or both will be
required to perform the function involved. However,
the Contractor shall always hire a PQP.
**************************************************************************
Provide a local exhaust system that creates a negative pressure of at least
0.51 mm 0.02 inches of water relative to the pressure external to the
enclosure and operate it continuously, 24 hours a day, until the temporary
enclosure of the asbestos control area is removed. Submit pressure
differential recordings for each work day to the [PQP] [and] [NC] for
review and to the Contracting Officer within 24 hours from the end of each
work day.
[1.5.7
Provide all records that document quality control for the decontamination
of reusable outer protective clothing.
][1.5.8
Submit written evidence that persons who decontaminate, store, or transport
asbestos contaminated clothing used in the performance of this contract
were duly notified in accordance with 29 CFR 1926.1101.
]1.6
EQUIPMENT
1.6.1
Rental Equipment
Provide a copy of the written notification to the rental company concerning
the intended use of the equipment and the possibility of asbestos
PART 2
PRODUCTS
2.1
ENCAPSULANTS
Shall conform to current USEPA requirements, shall contain no toxic or
hazardous substances as defined in 29 CFR 1926.59, and shall conform to the
following performance requirements.
SECTION 13281N