cast-in-place concrete walls. The wall top should
be protected by cap or by combination of clear
penetrating waterproofing solution and "steinakryl"
called, "Steinvari 2000." These products are
acceptable and available to the Iceland Prime
Contractor.
**************************************************************************
DIVISION 3:
EXTERIOR CONCRETE PAINT TABLE
A.
[New and uncoated existing] [and Existing, previously painted] concrete;
vertical surfaces, including undersides of balconies and soffits but
excluding tops of slabs:
1. [Latex
[New; MPI EXT 3.1A-G2 (Flat) / Existing; MPI REX 3.1A-G2 (Flat)
Primer:
Intermediate:
Topcoat:
MPI 10
MPI 10
MPI 10
System DFT: 3.5 mils 88 microns]
[New; MPI EXT 3.1A-G5 (Semigloss) / Existing; MPI EXT 3.1A-G5 (Semigloss)
Primer:
Intermediate:
Topcoat:
MPI 11
MPI 11
MPI 11
System DFT: 3.5 mils 88 microns]
[New; MPI EXT 3.1A-G6 (Gloss) / Existing; MPI REX 3.1A-G6 (Gloss)
Primer:
Intermediate:
Topcoat:
MPI 119
MPI 119
MPI 119
System DFT: 3.5 mils 88 microns]
Primer as recommended by manufacturer.
Topcoat:
Coating to match adjacent
surfaces.]
B.
[New and uncoated existing] [and Existing, previously painted] concrete,
textured system; vertical surfaces, including undersides of balconies and
soffits but excluding tops of slabs:
1. [Latex Aggregate
[New; MPI EXT 3.1B-G2 (Flat) / Existing; MPI REX 3.1B-G2 (Flat)
Primer:
Intermediate:
Topcoat:
MPI 42
MPI 10
MPI 10
System DFT: Per Manufacturer]
[New; MPI EXT 3.1B-G5 (Semigloss) / Existing; MPI REX 3.1B-G5 (Semigloss)
Primer:
Intermediate:
Topcoat:
MPI 42
MPI 11
MPI 11
System DFT: Per Manufacturer]
[New; MPI EXT 3.1B-G6 (Gloss) / Existing; MPI REX 3.1B-G6 (Gloss)
Primer:
Intermediate:
Topcoat:
MPI 42
MPI 119
MPI 119
System DFT: Per Manufacturer]
Texture - [Fine] [Medium] [Coarse]. Surface preparation and number of
coats in accordance with manufacturer's instructions. Topcoat: Coating
to match adjacent surfaces.]
C.
[New and uncoated existing] [and Existing, previously painted] concrete,
elastomeric System; vertical surfaces, including undersides of balconies
SECTION 09900
Page 42