PART 2
PRODUCTS
Not used.
PART 3
EXECUTION
3.1
PREPARATION
3.1.1
Protection
3.1.1.1
Notification
a. Notify the Contracting Officer [20] [_____] days prior to the start
of any lead work.
[
b. Occupant Notification
**************************************************************************
NOTE: Projects in target housing involving
improvement, or maintenance (renovation or repair),
that disrupt more than 2 square feet of painted
surface while being occupied requires occupant
notification prior to work.
**************************************************************************
Submit occupant written acknowledgment of the delivery of lead hazard
information pamphlet (EPA 747-K-99-001 "Protect Your Family From Lead
in Your Home") prior to commencing the renovation work for each
affected unit using language provided in 40 CFR 745 Subpart E.]
3.1.1.2
Lead Control Area
a. Physical Boundary - Provide physical boundaries around the lead
control area by roping off the area designated in the work plan or
providing curtains, portable partitions or other enclosures to ensure
that lead will not escape outside of the lead control area.
b. Warning Signs - Provide warning signs at approaches to lead control
areas. Locate signs at such a distance that personnel may read the sign
and take the necessary precautions before entering the area. Signs
shall comply with the requirements of 29 CFR 1926.62.
3.1.1.3
Furnishings
**************************************************************************
NOTE: Verify with the activity furniture or
equipment requirements.
**************************************************************************
[ The Government will remove furniture and equipment from the building before
lead work begins.]
[ Furniture [_____] and equipment will remain in the [building] [lead control
area]. Protect and cover furnishings or remove furnishings from the work
area and store in a location approved by the Contracting Officer.]
[ Existing [furniture] [and] [equipment] is lead contaminated,
[decontaminate] [dispose of as lead contaminated waste].]
SECTION 13282N
Page 16