1.5.2.8
Independent Testing Laboratory
The Contractor shall identify the independent testing laboratory selected
to perform the sample analyses and report the results. The testing
laboratory shall be completely independent from the Contractor as
recognized by federal, state or local regulations. Written verification of
the following criteria, signed by the testing laboratory principal and the
Contractor, shall be submitted:
(1) Phase contrast microscopy (PCM): The laboratory is fully
equipped and proficient in conducting PCM of airborne samples
using the methods specified by 29 CFR 1926.1101, OSHA method
ID-160, the most current version of NIOSH 94-113 Method 7400. The
laboratory shall be currently judged proficient (classified as
acceptable) in counting airborne asbestos samples by PCM by
successful participation in each of the last 4 rounds in the
American Industrial Hygiene Association (AIHA) Proficiency
Analytical Testing (PAT) Program or by participating in the AIHA
PAT Program, and being judged proficient in counting samples.
(2) Polarized light microscopy (PLM): The laboratory is fully
equipped and proficient in conducting PLM analyses of suspect ACM
bulk samples in accordance with 40 CFR 763, Subpart E, Appendix E;
the laboratory is currently accredited by NIST under the NVLAP for
bulk asbestos analysis and will use analysts with demonstrated
proficiency to conduct PLM analyses.
(3) Transmission electron microscopy (TEM): The laboratory is
[fully equipped and proficient in conducting TEM analysis of
airborne samples using the mandatory method specified by 40 CFR 763,
Subpart E, Appendix E; the laboratory is currently accredited by
NIST under the NVLAP for airborne sample analysis of asbestos by
TEM; the laboratory will use analysts with demonstrated
proficiency under NVLAP.] [proficient in conducting analysis for
low asbestos concentration, enhanced analysis of floor tiles and
bulk materials where multiple layers are present, using an
improved EPA test method titled, "Method for the Determination of
Asbestos in Bulk Building Materials".]
(4) PCM/TEM: The laboratory is fully equipped and each analyst
is proficient in conducting PCM and TEM analysis of airborne
samples using NIOSH 94-113 Method 7400 PCM and NIOSH 94-113 Method
7402 (TEM confirmation of asbestos content of PCM results) from
the same filter.
1.5.2.9
Disposal Facility, Transporter
The Contractor shall provide written evidence that the landfill to be used
is approved for asbestos disposal by the [USEPA] [and] [state] [and]
[local] regulatory agencies. Copies of signed agreements between the
Contractor (including subcontractors and transporters) and the asbestos
waste disposal facility to accept and dispose of all asbestos containing
waste shall be provided. The Contractor and transporters shall meet the
DOT requirements of 49 CFR 171, 49 CFR 172, and 49 CFR 173 as well as
registration requirements of 49 CFR 107 and other applicable state or local
requirements. The disposal facility shall meet the requirements of 40 CFR
61, Sections .154 or .155, as required in 40 CFR 61 150(b), and other
applicable state or local requirements.
SECTION 13280A