frames to adjoining construction.
6. Include a complete door schedule. The door
schedule should assign a separate number for each
opening and should indicate the door type and style,
material, design, size, thickness, hardware set
number, threshold material, if any.
**************************************************************************
PART 1
GENERAL
1.1
REFERENCES
**************************************************************************
NOTE: Issue (date) of references included in
provided by the latest guide specification. Use of
SpecsIntact automated reference checking is
recommended for projects based on older guide
specifications.
**************************************************************************
The publications listed below form a part of this specification to the
extent referenced. The publications are referred to within the text by the
basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM A 366/A 366M
(1997e1) Commercial Steel, Sheet,
Carbon,(0.15 Maximum Percent Cold-Rolled
ASTM A 569/A 569M
(1998) Steel, Carbon (0.15 Maximum
Percent), Hot-Rolled Sheet and Strip,
Commercial
ASTM A 653/A 653M
(2004a) Steel Sheet, Zinc-Coated
(Galvanized) or Zinc-Iron Alloy-Coated
(Galvannealed) by the Hot-Dip Process
ASTM G 60
(2001) Conducting Cyclic Humidity Exposures
NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS (NAAMM)
NAAMM HMMA 863
(2004) Guide Specifications for Detention
Security Hollow Metal Doors and Frames
1.2
SUBMITTALS
**************************************************************************
NOTE: Submittals must be limited to those necessary
for adequate quality control. The importance of an
item in the project should be one of the primary
factors in determining if a submittal for the item
should be required.
A "G" following a submittal item indicates that the
submittal requires Government approval. Some
submittals are already marked with a "G". Only
delete an existing "G" if the submittal item is not
SECTION 11193
Page 3