Waste receptacle shall be Type 304 stainless steel, designed for [recessed]
[surface] mounting. Reuseable liner, of the type standard with the
receptacle manufacturer, shall be provided. Capacity shall be not less
than [_____]cubic meters cubic feet. Receptacles with push doors and doors
for access to the waste compartment shall have continuous hinges. Locking
mechanism shall be [tumbler key lock] [_____].
2.2.24
Toilet Seat Cover Dispenser (TSCD)
Toilet seat cover dispensers shall be Type 304 stainless steel and shall be
[recessed mounted] [surface mounted]. Dispenser shall have a minimum
capacity of 500 seat covers.
2.2.25
Toilet Seat Cover/Tissue Dispenser/Waste Receptacle (TSCTDWR)
Toilet seat cover, tissue dispenser, and waste receptacle combination shall
be stainless steel and shall be [partition mounted] [recessed mounted]
[surface mounted]. Dispenser shall have a minimum of 500 [seat covers]
[seat covers per side] and [2] [4 (2 per side)] standard tissue rolls.
Waste receptacle shall have a reuseable liner of type standard with the
receptacle manufacturer. Capacity of receptacle shall be [_____] cubic
meters cubic feet. Locking mechanism shall be [tumbler key lock] [_____].
2.2.26
Electric Hand Dryer (EHD)
**************************************************************************
NOTE: Consider the use of electric hand driers in
public toilet areas that may not receive daily
custodian care and in areas where cleanliness is an
and hospitals.
**************************************************************************
Electric hand dryer shall be wall mounted and shall be designed to operate
element core rating of not more than 2100 watts. Dryer housing shall be of
single piece construction and shall be [white porcelain enamel] [chrome
plated steel] [baked electrostatically applied epoxy] [_____].
2.2.27
Diaper Changing Station (DCS)
**************************************************************************
NOTE: Omit requirement for integral dispenser for
sanitary liners if not required.
**************************************************************************
Diaper changing station shall be [recess mounted] [surface mounted] and
shall be fabricated of high impact plastic with no sharp edges. Unit fold
down platform shall be concave to the child's shape, equipped with nylon
and velcro safety straps and engineered to withstand a minimum static load
of [155 kg 340 lb] [113 kg 250 lb]. Unit shall have an integral dispenser
for sanitary liners. Safety graphics shall be pictorial for universal use.
Color shall be [_____] [as shown in Section 09915 COLOR SCHEDULE].
SECTION 10800