DIVISION 6: EXTERIOR WOOD; DRESSED LUMBER, PANELING, DECKING, SHINGLES PAINT
TABLE
[MPI EXT 6.5B-G6 (Gloss)
Primer:
Intermediate:
Topcoat:
MPI 27
MPI 27 [+NSA]
MPI 27 [+NSA]
System DFT: 5 mils 125 microns]]
**************************************************************************
NOTE: (DIVISION 9: EXTERIOR STUCCO PAINT TABLE)
Color: Main reason for painting stucco is to obtain
desired color. Before specifying paint systems,
coordinate with other specification sections to
confirm that stucco does not have special waterproof
finish or applied, colored cementitious finish and
that stucco does not have color pigment integral
with mix.
**************************************************************************
DIVISION 9:
EXTERIOR STUCCO PAINT TABLE
A.
[New] [and Existing] stucco:
1. [Latex
[New; MPI EXT 9.1A-G1 (Flat) / Existing; MPI REX 9.1A-G2 (Flat)
Primer:
Intermediate:
Topcoat:
MPI 10
MPI 10
MPI 10
System DFT: 4.5 mils 112 microns]
[New; MPI EXT 9.1A-G5 (Semigloss) / Existing; MPI REX 9.1A-G5 (Semigloss)
Primer:
Intermediate:
Topcoat:
MPI 11
MPI 11
MPI 11
System DFT: 4.5 mils 112 microns]
[New; MPI EXT 9.1A-G6 (Gloss) / Existing; MPI REX 9.1A-G6 (Gloss)
Primer:
Intermediate:
Topcoat:
MPI 119
MPI 119
MPI 119
System DFT: 4.5 mils 112 microns]
Primer as recommended by manufacturer. Topcoat: Coating to match
adjacent surfaces. On existing stucco, apply primer based on surface
condition.]
B.
[New] [and Existing] stucco, elastomeric system:
1. [Elastomeric Coating
New; MPI EXT 9.1C / Existing; MPI REX 9.1C
Primer:
Intermediate:
Topcoat:
N/A
MPI 113
MPI 113
System DFT: 16 mils 400 microns
Primer as recommended by manufacturer. Topcoat: Coating to match
adjacent surfaces. Surface preparation and number of coats in
accordance with manufacturer's instructions).
NOTE: Apply sufficient coats of MPI 113 to achieve a minimum dry film
thickness of 16 mils 400 microns.]
SECTION 09900
Page 54