SD-08 Manufacturer's Instructions
Setting and sealing materials
Glass setting
Submit glass manufacturer's recommendations for setting and
sealing materials and for installation of each type of glazing
material specified.[ Include cleaning instructions for plastic
sheets.]
**************************************************************************
NOTE: Use the following paragraph on Army projects.
**************************************************************************
[1.3
SYSTEM DESCRIPTION
Glazing systems shall be fabricated and installed watertight and airtight
to withstand thermal movement and wind loading without glass breakage,
gasket failure, deterioration of glazing accessories, and defects in the
work. Glazed panels shall comply with the safety standards, as indicated
in accordance with ANSI Z97.1. Glazed panels shall comply with indicated
wind/snow loading in accordance with ASTM E 1300.
]1.4
DELIVERY, STORAGE, AND HANDLING
Deliver products to the site in unopened containers, labeled plainly with
manufacturers' names and brands. Store glass and setting materials in
safe, enclosed dry locations and do not unpack until needed for
installation. Handle and install materials in a manner that will protect
them from damage.
1.5
ENVIRONMENTAL REQUIREMENTS
Do not start glazing work until the outdoor temperature is above 4 degrees C
40 degrees F and rising, unless procedures recommended by the glass
manufacturer and approved by the Contracting Officer are made to warm the
glass and rabbet surfaces. Provide ventilation to prevent condensation of
moisture on glazing work during installation. Do not perform glazing work
during damp or rainy weather.
1.6
WARRANTY
**************************************************************************
NOTE: The warranty clauses in this guide
specification have been approved by a Level I
Contracting Officer, and may be used without further
approval or request for waiver.
**************************************************************************
**************************************************************************
NOTE: Delete inapplicable paragraph[s].
**************************************************************************
1.6.1
Warranty for Insulating Glass Units
**************************************************************************
NOTE: For Air Force installations, select 10 years
for the guarantee period for control tower units.
SECTION 08800
Page 8