Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are [for Contractor Quality Control
approval.][for information only. When used, a designation following the
"G" designation identifies the office that will review the submittal for
the Government.] The following shall be submitted in accordance with
Section 01330 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Installation[; G][; G, [_____]]
For special doors or standard doors with appreciable
indicating the door location and showing dimensions, materials,
fabrication methods, hardware, and accessories in sufficient
detail to enable the Contracting Officer to check compliance with
contract documents. Weld symbols used shall conform to AWS A2.4.
These drawings need not be submitted for standard doors for which
manufacturer's catalog data is submitted.
SD-03 Product Data
Door Description[; G][; G, [_____]]
Data on standard blast doors consisting of catalog cuts,
brochures, circulars, specifications, and product data that show
complete dimensions and completely describe overpressure ratings,
rebound ratings, doors, frames, anchors, hardware, and accessories.
Detailed structural analysis and design calculations
demonstrating resistance to blast when blast resistance is not
demonstrated by prototype tests. Design calculations shall
demonstrate adequacy under the blast effects specified or
indicated. Design calculations shall include a sketch of the
overpressure waveform; dimensioned sketches of blast resisting
elements such as door members, frame members, latches, and hinges;
section properties for blast resisting members including built-up
sections; the standard under which steel is produced; static and
dynamic material strength properties; the resistance, stiffness,
mass, elastic natural period, and elastic deflection for flexural
members; and the peak deflection, peak support rotation, and time
to peak deflection for door members in flexure. Design
calculations shall cover initial response, rebound, and all
secondary items such as shear, welds, local buckling, web
crippling, hinges, and latches.
Door Description
Manufacturer's instructions for installation and field testing.
Manufacturer's Field Service
Information describing training to be provided, training aids to
be used, and background data on the personnel conducting the
training.
SECTION 08390