#.1
SCHEDULES
Submit door and frame locations.
PART 2
PRODUCTS
2.1
STANDARD STEEL DOORS
SDI A250.8, except as specified otherwise. Prepare doors to receive
hardware specified in Section 08710 DOOR HARDWARE. Undercut where
indicated. Exterior doors shall have top edge closed flush and sealed to
prevent water intrusion. Doors shall be 44.5 mm 1 3/4 inches thick, unless
otherwise indicated.
2.1.1
Classification - Level, Performance, Model
**************************************************************************
NOTE: When a door level is not required, delete the
entire paragraph for that level. Door levels for
various locations should be determined in accordance
with the following list and sound judgment.
Closet doors (without locks) ............. Level 1
Individual offices, storage rooms,
classrooms, patients' rooms,
bathrooms, and bedrooms (except
BEQ bedrooms) ......................... Level 2
BEQ sleeping room entrance doors and interior egress
doors ......................... Level 3
Exterior Main entrance and circulation doors and
other locations ......................... Level 4
Model designations are as follows:
Model 1 Full Flush Design
Model 2 Seamless Design
Model 3, Stile and Rail
Where appearance is important and edge seams are
objectionable, use Model 2.
Core constructions shall be at the manufacturer's
discretion and are as follows:
a. Kraft/Paper Honeycomb
b. Polyurethane
c. Polystyrene
d. Mineral Board
e. Vertical Steel Stiffeners
**************************************************************************
2.1.1.1
Standard Duty Doors
SDI A250.8, Level 1, physical performance Level
c, Model [1] [2], of size(s) and design(s) indicated and core construction
as required by the manufacturer. Provide [where shown] [for doors No.
[_____]].
SECTION 08110
Page 8