prior to cutting and shipping.
2.7
BASE COAT
Manufacturer's standard product and compatible with other systems
components.
2.8
PORTLAND CEMENT
Conform to ASTM C 150, Type I or II as required, fresh and free of lumps,
and approved by the systems manufacturer.
2.9
REINFORCING FABRIC
Reinforcing fabric mesh shall be alkali-resistant, balanced, open weave ,
glass fiber fabric made from twisted multi-end strands specifically treated
for compatibility with the other system materials, and comply with ASTM E
2098 and as recommended by EIFS manufacturer.
2.11
FINISH COAT
Manufacturer's standard product conforming to the requirements in the
paragraph on Sub-Component Requirements and Tests. For color consistency,
2.12
SEALANT PRIMER
Non-staining, quick-drying type recommended by sealant manufacturer and
EIFS manufacturer.
2.13
ACCESSORIES
Conform to recommendations of EIFS manufacturer, including trim, edging,
anchors, expansion joints. All metal items and fasteners to be corrosion
resistant.
2.14
JOINT SEALANT
Non-staining, quick-drying type meeting ASTM C 920, as Type S or M, minimum
Grade NS, minimum Class 25 and compatible with the finish system type and
grade, and recommended by both the sealant manufacturer and EIFS
manufacturer.
2.15
BOND BREAKER
As required by EIFS manufacturer and recommended by sealant manufacturer
and EIFS manufacturer.
2.16
BACKER ROD
Closed cell polyethylene free from oil or other staining elements and as
recommended by sealant manufacturer and EIFS manufacturer. Do not use
absorptive materials as backer rod. The backer rod should be sized 25
percent larger than the width of the joint.
SECTION 07240