01330 SUBMITTAL PROCEDURES:
SD-03 Product Data
Sampling and Analysis Plan; G, [_____]
The SAP including the Field Sampling Plan (FSP) and the Quality
Assurance Project Plan (QAPP), no later than [_____] days after
receipt of notice to proceed.
SD-06 Test Reports
QA Sample Collection and Analysis
The QA Laboratory Advance Notification (QALAN) shall be provided
to the QA laboratory at least [10 business] [_____] days before
the initial shipment of samples.
Chemistry Data Package
The chemistry data package shall be provided [to the QA lab] [to
the process treatment personnel] [as an attachment to the CDFR]
[every [_____] [days] [weeks] of the project] [at the end of the
project].
Chemical Data Final Report; G, [_____]
The CDFR, within [_____] days of completing work at the site,
before final payment. Each report shall be labeled with the
contract number, project name and location.
1.6
QUALITY ASSURANCE ELEMENTS
**************************************************************************
NOTE: All HTRW projects require a comprehensive and
multifaceted approach to quality control and quality
assurance in order to achieve and document
attainment of appropriate quality for the intended
data usage. The designer, in consultation with the
technical team, can choose from several techniques
to monitor and ensure the quality of the chemical
data. The designer must define the appropriate QA
elements to be applied to the project, as well as
the frequency of application, and any contingency or
corrective action protocols necessary in the event
of deficiency or failure. EM 200-1-6 provides a
description of each Chemical Data Quality Management
(CDQM) activity.
**************************************************************************
The Contractor shall be responsible for the following QA elements necessary
to monitor and ensure the quality of chemical data produced.
1.6.1
Laboratory Validation Requirements
The Contractor shall propose the minimum number of laboratories that can
attain or have attained U.S. Army Corps of Engineers (USACE) validation in
accordance with EM 200-1-1 and consistent with contract required chemical
data quality. The Contractor may propose laboratories that shall
SECTION 01450A
Page 10