These units shall be constructed of coated steel or injection molded
plastic and shall accommodate either legal or letter size lengths. Unit
shall not be freestanding and shall be provided as shown on the drawings.
2.6.7
Wall Mounted Components
Wall tracks shall be utilized when components are shown attached directly
to wall surfaces. Tracks shall be of heavy duty extruded metal. Finish
and color of tracks shall match the panel trim. Vertically aligned tracks
shall be slotted on 25 mm 1 inch centers in heights required. Slot spacing
shall match slot spacing for wall panels.
2.6.8
CPU Holder
A mounting device shall be provided to support the computer hard drive.
Desk top and floor locations are not acceptable.
2.7
MISCELLANEOUS HARDWARE
Brackets, supports, hangers, clips, panel supported legs, connectors,
adjustable feet, cover plates, stabilizers, and other miscellaneous
hardware shall be provided.
2.8
LOCKS AND KEYING
**************************************************************************
NOTE: The quantity of different key operations
required is dependent on the size of the project.
The number specified should not exceed the quantity
of workstations. The maximum quantity utilized
shall not exceed 150.
**************************************************************************
Drawers, flipper door cabinets, and lateral files shall have keyed locks,
unless otherwise noted. Field changeable lock cylinders shall be provided
with a minimum of [100] [_____] different key options. Each workstation
shall be individually keyed and locks within a workstation shall be keyed
alike. Drawers within a pedestal shall be lockable either by a central
lock that controls all pedestals under one work surface or an individual
keyed lock in each pedestal. Central file and storage units which are
grouped together but are not a part of a workstation shall be keyed alike
unless otherwise specified. Door panels shall have keyed [door knob]
[_____] set. Two keys shall be provided for each lock or 2 keys per
workstation when keyed alike, and 3 master keys shall be provided per area
as shown on the contract drawings. Keys and lock cylinders shall be
numbered for ease of replacement. Locks shall be clearly labeled with a
key number, except for those manufacturers who have removal format locks.
2.9
ELECTRICAL
**************************************************************************
NOTE: It is recommended that the type of cabling
assembly (wiring, harnesses, or buses) be left as a
Contractor selection unless necessary to restrict
for compatibility with existing equipment.
**************************************************************************
Both powered and nonpowered panels [and spine walls] shall have base
raceways capable of distributing power circuits, [communication cables]
SECTION 12705