of equipment shall essentially duplicate equipment that has been in
satisfactory use at least 2 years prior to bid opening.
1.7
DELIVERY AND STORAGE
Materials shall be wrapped for shipment and storage, delivered to the
jobsite in manufacturer's original packaging, and stored in a clean, dry
area in accordance with manufacturer's instructions.
1.8
WARRANTY
Manufacturer's standard performance guarantees or warranties that extend
beyond a one year period shall be provided.
1.9
EXTRA STOCK
**************************************************************************
NOTE: A sufficient number of message panels/bars
and letters for future use for changes and message
replacement shall be specified.
**************************************************************************
The Contractor shall provide [_____] extra interchangeable message panels
and extra stock of the following: [[_____] message bars of each color and
size for sign types [_____].] [[_____] pressure-sensitive letters in each
color and size for sign type [_____].] [[_____] changeable message strips
for sign type [_____].]
PART 2
PRODUCTS
2.1
MODULAR EXTERIOR SIGNAGE SYSTEM
**************************************************************************
NOTE: Omit signage systems not required for project.
Signage for Navy projects should be designed in
accordance with the Activity's Base Exterior
Architectural Guide or Base Signage Guide. Check
with activity concerning standards on safety
Enamel finish is more economical than anodized, but
may not perform as well; therefore, may not be cost
effective. Designer should investigate local
conditions to make determination.
**************************************************************************
Exterior signage shall consist of a system of coordinated directional,
identification, and regulatory type signs located where shown. Dimensions,
details, materials, message content, and design of signage shall be as
shown.
2.1.1
Free-Standing Base Mount Pylon/Monolith Type Signs
**************************************************************************
NOTE: Drawings should show mounting heights and
mounting details.
**************************************************************************
SECTION 10430
Page 8