herein includes surface color and pattern."
Prior to specifying a custom color finish, research
to determine if additional cost and lead time is
feasible. Note there is often a minimum order
requirement; this requirement will also affect
future orders.
When a manufacturer's name, stock number, pattern,
and color is used, be certain that the product
conforms to this specification, as edited.
**************************************************************************
Color shall be [in accordance with Section 09915 COLOR SCHEDULE.] [as
indicated on the drawings.] [selected from manufacturers standard colors.]
[[______.] Color listed is not intended to limit the selection of equal
colors from other manufacturers.]
PART 3
EXECUTION
3.1
INSTALLATION
3.1.1
Corner Guards and Wall Guards (Bumper Guards)
Material shall be mounted at location indicated in accordance with
manufacturer's recommendations.
3.1.2
Surfaces to receive protection shall be clean, smooth, and free of
obstructions. Protectors shall be installed after frames are in place, but
prior to hanging of doors, in accordance with manufacturer's specific
instructions. Adhesives shall be applied in controlled environment in
accordance with manufacturer's recommendations. Protection for fire doors
and frames shall be installed in accordance with NFPA 80.
3.1.3
Stainless Steel Guards
a.
Mount guards on external corners of interior walls, partitions and
columns as [shown] [per manufacturer's recommendations].
b.
Where corner guards are installed on walls, partitions or columns
finished with plaster or ceramic tile, [anchor corner guards as
indicated] [provide continuous 1.5 mm 16 gage thick, perforated,
galvanized z-shape steel anchors welded to back edges of corner
guards and [wired to metal studs] [expansion bolted to concrete or
masonry with four 10 mm 3/8 inch diameter bolts, spaced 400 mm 16
inches on centers]]. Coat back surfaces of corner guards, where
shown, with a non-flammable, sound deadening material. Corner
guards shall overlap finish plaster surfaces.
(1) Where corner guards are installed on exposed structural
glazed facing tile units or masonry wall, partitions or columns,
[anchor corner guards as shown on the drawings] [anchor corner
guards to existing walls with 6 mm 1/4 inch oval head stainless
steel countersunk expansion or toggle bolts] [anchor corner guards
with four nominal 1.3 mm 0.0516 inch thick, adjustable galvanized
steel anchors, spaced as shown]. Grout spaces solid between
SECTION 10260
Page 11