Architect-Engineer; "DO" for District Office
(Engineering Division or other organization in the
District Office); "AO" for Area Office; "RO" for
Resident Office; and "PO" for Project Office. Codes
following the "G" typically are not used for Navy
projects.
Submittal items not designated with a "G" are
considered as being for information only for Army
projects and for Contractor Quality Control approval
for Navy projects.
**************************************************************************
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are [for Contractor Quality Control
approval.][for information only. When used, a designation following the
"G" designation identifies the office that will review the submittal for
the Government.] The following shall be submitted in accordance with
Section 01330 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Drawings including installation details, ceiling framing, and
furring.
SD-03 Product Data
Lathing Installation
Manufacturer's pre-printed descriptive data, catalog cuts, and
SD-04 Samples
Gypsum Plaster
[One] [_____] 1 m 36 inch square sample panel of each specified
finish.
SD-07 Certificates
Qualifications
Manufacturer's experience in specified work.
Gypsum Plaster
Certification indicating that factory-mixed plaster provides a
minimum compressive strength of not less than 6.9 MPa 1000 psi
when tested in accordance with ASTM C 472.
1.3
QUALIFICATIONS
Manufacturer shall specialize in manufacturing the types of material
specified, and shall have a minimum of [5] [_____] years of documented
successful experience. Applicator shall specialize in the type of lath and
plaster work required to meet requirements, with a minimum of [3] [_____]
SECTION 09200A