are not required at hinge stiles on doors equipped
with "swing clear" hinges.
**************************************************************************
BHMA A156.6, stainless steel, of same height as armor plates.
Apply to
[hinge stile] [lock stile] [meeting stiles].
2.3.17
Door Stops and Silencers
**************************************************************************
NOTE: Specify wall bumpers Type L02251 wherever
practical, except where they would be mounted on
stud walls or partitions. Use floor stops only
where necessary to prevent doors from hitting towel
bars or similar items, as they create stumbling
hazards and interfere with floor cleaning equipment.
**************************************************************************
BHMA A156.16. Silencers Type L03011.
Provide three silencers for each
single door, two for each pair.
2.3.18
Padlocks
**************************************************************************
NOTE: See referenced specification for types,
grades and options available.
**************************************************************************
ASTM F 883.
2.3.19
Thresholds
**************************************************************************
NOTE: Where vertical rod exit devices are used, and
for other outswinging exterior doors, BHMA A156.21,
type J35100, is recommended.
**************************************************************************
BHMA A156.21. Use J35100, with vinyl or silicone rubber insert in face of
stop, for exterior doors opening out, unless specified otherwise.
2.3.20
Weather Stripping Gasketing
**************************************************************************
NOTE: Weather stripping is also specified in
Section 08110, "Steel Doors and Frames," Section
08120, "Aluminum Doors and Frames," and Section
08210, "Wood Doors." Coordinate requirements to
avoid conflict and duplication. Do not use
interlocking type or spring tension type on metal
doors and frames.
**************************************************************************
**************************************************************************
NOTE: Maximum air leakage rates are 2.19 x 10-5 cms
per sq m 0.5 cfm per sq. ft. of door area for
residential swinging doors and 5.48 x 10-5 cms per
sq m 1.25 cfm per sq. ft. of door area for
non-residential swinging doors.
SECTION 08710
Page 17