3.4
KEY CABINET AND CONTROL SYSTEM
Locate where [directed] [indicated]. Tag one set of file keys and one set
of duplicate keys. Place other keys in appropriately marked envelopes, or
tag each key. Furnish complete instructions for setup and use of key
control system. On tags and envelopes, indicate door and room numbers or
3.5
FIELD QUALITY CONTROL
After installation, protect hardware from paint, stains, blemishes, and
other damage until acceptance of work. Submit notice of testing 15 days
before scheduled, so that testing can be witnessed by the Contracting
Officer. Adjust hinges, locks, latches, bolts, holders, closers, and other
items to operate properly. Demonstrate that permanent keys operate
respective locks, and give keys to the Contracting Officer. Correct,
repair, and finish, as directed, errors in cutting and fitting and damage
to adjoining work.
3.6
HARDWARE SETS
**************************************************************************
NOTE: Coordinate this section with Section 08120,
"Aluminum Doors and Frames."
Either list hardware set numbers on the drawings or
list doors by number in each hardware set. List
hardware sets in the following format:
SAMPLE LIST OF HARDWARE SETS
HW-1 (Doors 1 and 2, each pair)
3 Pair Hinges
A2111 x 623 x NRP
1 Three-Point Lock
E8271
2 Closers
C02021
2 Wall Bumpers
L02251
2 Pulls
Extruded aluminum with
decorative panels
2 Push Bars
Extruded aluminum with
decorative panels
1 Threshold
Type 26
HW-2 (Doors 3 and 4, each pair)
3
Pair Hinges
A2112 x 626 x NRP
2
Exit Devices
Type 1-05 x 630
1
Removable Mullion
Type 22
2
Closers
C02021
2
Kick Plates
J102 x 630
2
Wall Bumpers
L02251
1
Threshold
Type 26 x insert
1
Set Weatherstripping
R0D165
HW-3 (Doors 5, 7, 9, each leaf)
1 1/2 Pair Hinges
A2112 x 626 x NRP
1 Lockset
F04 x 630
1 Closer
C02021
SECTION 08710
Page 21