c.
Tabulation showing which key fits which door.
d.
Copy of floor plan showing doors and door numbers.
e.
Listing of 20 percent more key cuts than are presently required in
each master system.
1.5
QUALITY ASSURANCE
1.5.1
Hardware Manufacturers and Modifications
Provide, as far as feasible, locks, hinges, [pivots,] and closers of one
lock, hinge, [pivot,] or closer manufacturer's make. Modify hardware as
necessary to provide features indicated or specified.
1.6
DELIVERY, STORAGE, AND HANDLING
**************************************************************************
NOTE: Whenever construction master keying is
required, permanent keys (and removable cores)
should be sent directly to the Contracting Officer.
**************************************************************************
Deliver hardware in original individual containers, complete with necessary
appurtenances including fasteners and instructions. Mark each individual
container with item number as shown in hardware schedule. [Deliver
permanent keys [and removable cores] to the Contracting Officer, either
directly or by certified mail. Deliver construction master keys with the
locks.]
PART 2
PRODUCTS
2.1
TEMPLATE HARDWARE
Hardware to be applied to metal [or to prefinished doors] shall be made to
template. Promptly furnish template information or templates to door and
frame manufacturers. Template hinges shall conform to BHMA A156.7.
Coordinate hardware items to prevent interference with other hardware.
2.2
HARDWARE FOR FIRE DOORS AND EXIT DOORS
Provide all hardware necessary to meet the requirements of NFPA 80 for fire
doors and NFPA 101 for exit doors, as well as to other requirements
specified, even if such hardware is not specifically mentioned under
paragraph entitled "Hardware Schedule." [Swinging hardware for tin-clad
fire doors shall conform to UL 14C.] Such hardware shall bear the label of
Underwriters Laboratories, Inc., and be listed in UL Bld Mat Dir or labeled
and listed by another testing laboratory acceptable to the Contracting
Officer.
2.3
HARDWARE ITEMS
**************************************************************************
NOTE: It is essential for the specifier to have
current editions of the BHMA standards, available
from Builders Hardware Manufacturers Association, 60
East 42nd Street, New York, New York 10165. The
specifier should also have publications of the Door
and Hardware Institute (DHI), 7711 Old Springhouse
SECTION 08710
Page 7