USACE / NAVFAC / AFCESA
UFGS-08510 (August 2001)
------------------------------
Preparing Activity: NAVFAC
Superseding
UFGS-08510 (September 1999)
UNIFIED FACILITIES GUIDE SPECIFICATIONS
References are in agreement with UMRL dated 23 June 2005
Latest change indicated by CHG tags
**************************************************************************
SECTION 08510
STEEL WINDOWS
08/01
**************************************************************************
NOTE: This guide specification covers the
requirements for standard steel windows.
Comments and suggestions on this guide specification
are welcome and should be directed to the technical
proponent of the specification. A listing of
technical proponents, including their organization
designation and telephone number, is on the Internet.
Recommended changes to a UFGS should be submitted as
a Criteria Change Request (CCR).
Use of electronic communication is encouraged.
Brackets are used in the text to indicate designer
choices or locations where text must be supplied by
the designer.
**************************************************************************
**************************************************************************
NOTE: On the drawings, show:
1. Sizes and types of windows; metal sub-frames,
casings, or stools, if any; and hardware
2. Sizes, location and swing of ventilators;
location and details of fixed sash
3. Method of anchoring windows to adjoining
construction; size and types of clips, anchors,
screws, or other fasteners
4. Details of non-structural mullions and mullion
covers; details for anchoring and reinforcing
non-structural mullions at windows to receive window
5. Locations of special glass such as tempered,
insulating, heat-absorbing, light-reducing,
SECTION 08510
Page 3