2.1.1.3
Texture
[Stucco embossed.][Smooth.][Smooth with raised intermediate ribs for added
stiffness].
2.1.1.4
Color
**************************************************************************
NOTE: Check with the facility regarding color
selection. Use only manufacturer's standard colors.
Delete this paragraph if mill finish has been
selected.
**************************************************************************
[As selected.] [Blue] [Red] [[_____], No. [_____]] exterior.
2.1.1.5
Configuration
**************************************************************************
NOTE: The height of vertical legs should not be
less than 50 mm 2 inches on roofs having a slope
less than 2 in 12. The occurrence of ice dams or
other water flow obstructions should be considered
when determining the vertical leg height.
**************************************************************************
Provide panels of continuous lengths from ridge to eaves or from top to
eaves on shed roof designs. Panels shall be [300] [_____] mm [12] [_____]
inches wide with a minimum [50] [_____] mm [2.0] [_____] inch high vertical
legs and two [9.4 mm0.37 inch] [_____] stiffening ribs at 100 mm 4 inches
on center between the legs to minimize oil-canning and telegraphing of
structural members. Leading vertical leg shall have a continuous groove in
the rib top for anti-siphon protection when hook-rib top of next panel is
locked over leading vertical leg to form the standing seam. Panels from
coil stock shall be formed without warping, waviness or ripples not a part
of the panel profile, and shall be free of damage to the finish coating
system.
[2.1.1.6
Prefinished Coating System
**************************************************************************
NOTE: Delete this paragraph if mill finish has been
selected.
**************************************************************************
Fluorocarbon baked enamel, factory-applied, minimum total dry film nominal
thickness of [0.0175] [0.050] [_____] mm [0.7] [2.0] [_____] mils, and
conforming to test requirements specified herein. Provide prefinished
coating system on [both faces.] [the exterior face.] Interior face shall
receive same coating system, or, at the manufacturer's option, receive a
coat of acrylic wash coat applied to a minimum total dry film nominal
thickness of 0.005 mm 0.20 mil. Color shall be [as specified] [as selected
from the manufacturer's standard colors].
]2.2
ATTACHMENT CLIPS
**************************************************************************
NOTE: Add the appropriate choice(s) for the
attachment clip(s) used in the design. Insert
SECTION 07612N
Page 15