NOTE: Edit the product data submission requirements
as necessary for the system specified. Include
bracketed requirements as applicable to the system
being specified (e.g., torch applied systems may not
require asphalt in the installation).
**************************************************************************
Modified Bitumen Sheets; G, [_____]
[
Asphalt]
[
Cold-Applied Membrane Adhesive; G, [_____]]
[
Primer; G, [_____]
Modified Bitumen Roof Cement; G, [_____]
[
Pre-Manufactured Accessories]
Fasteners And Plates; G, [_____]
Vapor Pressure Relief Vents
Sample Warranty certificate; G, [_____]
Submit all data required by Section 07220 ROOF AND DECK
INSULATION, together with requirements of this section. Data
shall include written acceptance by the roof membrane manufacturer
of the products and accessories provided. Products shall be as
listed in the applicable wind uplift and fire rating
classification listings, unless approved otherwise by the
Contracting Officer.
SD-05 Design Data
**************************************************************************
NOTE: Coordinate with requirements of "Wind Uplift"
paragraph. Include bracketed requirement where
non-rated systems may be permissible.
**************************************************************************
Wind uplift calculations; G
[
Engineering calculations validating the wind resistance of
non-rated roof system.]
SD-07 Certificates
Show evidence that products used within this specification are
manufactured in the United States.
Qualification of Manufacturer
Certify that the manufacturer of the modified bitumen membrane
SECTION 07550
Page 9