1.5
DELIVERY, STORAGE, AND HANDLING
Deliver, store, and handle panel materials, bulk products, accessories, and
other manufactured items in a manner to prevent damage and deformation, as
recommended by the manufacturer, and as specified.
1.5.1
Delivery
Deliver materials to the site in dry and undamaged condition. Provide
adequate packaging to protect materials during shipment. Crated materials
shall not be uncrated until ready for use, except for inspection.
Immediately upon arrival of materials at jobsite, inspect materials for
damage, deformation, dampness, and staining. Remove affected materials
from the site. Remove moisture from wet materials not otherwise affected,
restack and protect from further moisture exposure.
1.5.2
Storage
Stack materials stored on site on platforms or pallets, and cover with
tarpaulins or other weathertight covering which prevents trapping of water
or condensation under the covering. Store wall panels so that water which
may have accumulated during transit or storage will drain off. Do not
store panels in contact with materials that might cause staining. Storage
accommodations for metal wall panels shall provide good air circulation and
protection from surface staining. Secure coverings and stored items to
protect from wind displacement.
1.5.3
Handling
Handle materials in a manner to avoid damage. Select and operate material
1.6
WARRANTIES
The Contractor shall provide a weathertight material and workmanship
warranty for the metal wall panel system installation for a period of
[5][10][20] years and to include a manufacturer's [5][10][_____] year
warranty against cracking, peeling, or delamination of the color finish and
corrosion of the base metal, and 10 year warranty against the corrosion of
fasteners caused by ordinary wear and tear by the elements. The warranties
shall start upon final acceptance of the work or the date the Government
PART 2
PRODUCTS
2.1
WALL PANEL
**************************************************************************
NOTE: This paragraph will be edited to reflect the
project requirements with regard to panel finish,
edge configuration, and fastening system. Except
for special situations, steel and aluminum will be
retained as options for wall panel materials. Where
appearance is not critical, the overlapping
configurations and exposed penetrating fastener
options may remain as contractor options.
**************************************************************************