approval.][for information only. When used, a designation following the
"G" designation identifies the office that will review the submittal for
the Government.] The following shall be submitted in accordance with
Section 01330 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
SD-04 Samples
Expansion Joint Materials
Clay or Shale Brick
Concrete Masonry Unit
Prefaced Concrete Masonry Unit
Sample Panel
A portable panel, approximately 600 by 600 mm 2 by 2 feet,
containing approximately [24 brick facings] [24 concrete masonry
units] to establish the range of color and texture. One of each
type of masonry veneer anchor used.
SD-06 Test Reports
Calculations
Calculations demonstrating the structural adequacy of steel
lintels and shelf angles for the calculated gravity loads being
supported; this analysis shall be in accordance with AISC 316.
Test results demonstrating that the veneer anchors are
structurally adequate to resist the specified loadings shall be
submitted for approval. Calculations demonstrating the insulation
shown on the drawings provides the specified U-value for heat
transmission of the completed exterior wall construction; this
analysis shall be in accordance with ASHRAE Fundamentals Handbook.
the insulation, the vapor barrier and the moisture barrier.
SD-07 Certificates
Clay or Shale Brick
Concrete Masonry Unit
Joint Reinforcement
Expansion Joint Materials
Insulation
Exterior Sheathing
Moisture Barrier
Vapor Retarder
Welding
Certificates stating that the materials and welders meet the
requirements specified. Each certificate shall be signed by an
authorized certification official and shall include their
organization and position and shall identify the products covered
under their certifying signature.
SECTION 04810
Page 7