SD-05 Design Data
Pre-mixed Mortar[; G][; G, [_____]]
Unit Strength Method[; G][; G, [_____]]
Pre-mixed mortar composition. Calculations and certifications
of masonry unit and mortar strength.
SD-06 Test Reports
Efflorescence Test[; G][; G, [_____]]
Field Testing of Mortar[; G][; G, [_____]]
Field Testing of Grout[; G][; G, [_____]]
Prism tests[; G][; G, [_____]]
Masonry Cement[; G][; G, [_____]]
Fire-rated CMU[; G][; G, [_____]]
Test reports from an approved independent laboratory. Test
reports on a previously tested material shall be certified as the
same as that proposed for use in this project.
Special Inspection[; G][; G, [_____]]
Copies of masonry inspector reports.
SD-07 Certificates
Clay or Shale Brick
Concrete Brick
Concrete Masonry Units (CMU)
Control Joint Keys
Expansion-Joint Materials
Joint Reinforcement
Reinforcing Steel Bars and Rods
Masonry Cement
Mortar Coloring
Insulation
Precast Concrete Items
Admixtures for Masonry Mortar
Admixtures for Grout
Certificates of compliance stating that the materials meet the
specified requirements.
Insulation
Certificate attesting that the polyurethane or polyisocyanurate
insulation furnished for the project contains recovered material,
and showing an estimated percent of such recovered material.
SD-08 Manufacturer's Instructions
Masonry Cement
When masonry cement is used, submit the manufacturer's printed
instructions on proportions of water and aggregates and on mixing
to obtain the type of mortar required.
SECTION 04200