construction, additional masonry openings are required, the
approved shop drawings shall be resubmitted with the additional
openings shown along with the proposed changes. Location of these
additional openings shall be clearly highlighted. The minimum
scale for wall elevations shall be 1 to 50 1/4 inch per foot.
Reinforcement bending details shall conform to the requirements of
ACI SP-66.
SD-03 Product Data
Clay or Shale Brick[; G][; G, [_____]]
Concrete Brick[; G][; G, [_____]]
Insulation[; G][; G, [_____]]
Flashing[; G][; G, [_____]]
Water-Repellant Admixture[; G][; G, [_____]]
Manufacturer's descriptive data.
SD-04 Samples
Concrete Masonry Units (CMU)[; G][; G, [_____]]
Concrete Brick[; G][; G, [_____]]
Stone Items[; G][; G, [_____]]
Clay or Shale Brick[; G][; G, [_____]]
Color samples of three stretcher units and one unit for each
type of special shape. Units shall show the full range of color
and texture. Submit sample of colored mortar with applicable
masonry unit.
Anchors, Ties, and Bar Positioners[; G][; G, [_____]]
Two of each type used.
Expansion-Joint Materials[; G][; G, [_____]]
One piece of each type used.
Joint Reinforcement[; G][; G, [_____]]
One piece of each type used, including corner and wall
intersection pieces, showing at least two cross wires.
Insulation[; G][; G, [_____]]
One piece of board type insulation, not less than 400 by 600 mm
16 by 24 inches in size, containing the label indicating the rated
permeance and R-values.
Portable Panel[; G][; G, [_____]]
One panel of clay or shale brick, 600 by 600 mm 2 by 2 feet,
containing approximately 24 brick facings to establish range of
color and texture.
SECTION 04200
Page 10