TOLERANCES FOR CAST-IN-PLACE, VERTICALLY SLIPFORMED
BUILDING ELEMENTS
Wall thickness ............................................ +19 mm
............................................ -10 mm
(4)
Relative alignment
Formed surface slope with respect to the
specified plane ................................. 19 mm in 3000 mm
TOLERANCES FOR MASS CONCRETE STRUCTURES OTHER THAN
BUILDINGS
(1)
Vertical alignment
Visible surfaces ........................................... 30 mm
Concealed surfaces ......................................... 65 mm
Side walls for radial gates and similar
watertight joints ........................................... 5 mm
(2)
Lateral alignment
Visible surfaces ........................................... 30 mm
Concealed surfaces ......................................... 65 mm
(3)
Level alignment
Visible flatwork and formed surfaces ....................... 13 mm
Concealed flatwork and formed surfaces ..................... 25 mm
Sills for radial gates and similar
watertight joints ........................................... 5 mm
(4)
Relative alignment
Formed surface slope with respect to the specified plane
Slopes in lateral and level alignments
Visible surfaces ......................... 7 mm in 3000 mm
Concealed surfaces ...................... 13 mm in 3000 mm
Slopes in vertical alignment
Visible surfaces ........................ 13 mm in 3000 mm
Concealed surfaces ...................... 25 mm in 3000 mm
SECTION 03700
Page 22