plus or minus 0.5 mm 0.020 inch tolerance. The coating shall have an 85
durometer hardness, ASTM D 3363. The finish shall be slip-resistant.
2.1.5.4
Concrete
Concrete shall conform to Section 02770 CONCRETE SIDEWALKS AND CURBS AND
GUTTERS.
2.1.5.5
Precast Concrete
Precast concrete material shall conform to Section 03413A PRECAST
ARCHITECTURAL CONCRETE.
2.1.5.6
Cast-In Place Concrete
Cast-in-place concrete material shall conform to Section 03300A
CAST-IN-PLACE ARCHITECTURAL CONCRETE.
2.1.6
Wood Sealants
Exposed wood surfaces shall have factory applied prime coat with a minimum
[2] [_____] spray coats of two-component polyurethane or approved
2.1.6.1
Paint
Paint shall be factory applied to a minimum 2 coats. Paint shall comply
with Section 09900 PAINTING, GENERAL and be weather resistant, cracking,
peeling and fading.
2.1.6.2
Sealants
Sealants shall seal all applied surfaces from air.
Sealants containing
pesticide are prohibited.
2.1.7
Color
Color shall be provided [as indicated] [in accordance with Section 09915
COLOR SCHEDULE] [_____].
2.2
EQUIPMENT
**************************************************************************
NOTE: Ensure the play events selected are
age-appropriate for the age group designated to use
them.
Playground Areas Other Than Child Development
Centers (CDC): CPSC Pub No 325 and ASTM F 1487 both
describe the requirements for children from the
toddler through pre-teen age group (2 through 12
years of age). Consult TM 5-803-11, Children's
Outdoor Play Areas, for guidance concerning children
in the infant through pre-toddler age groups (less
than 12 months through 2 years of age).
Child Development Centers (CDC): The CDC program
accommodates children from 6 weeks through 8 years
of age. The CDC outdoor play area requirements for
SECTION 02882
Page 17