Minimum Moment
Nominal
Minimum
of Inertia of
Size
Wall Area
Wall Section
(in.)
(square in/ft)
(in to the 4th/in)
_________________________________________________________
12
1.50
0.024
15
1.91
0.053
18
2.34
0.062
24
3.14
0.116
30
3.92
0.163
36
4.50
0.222
42
4.69
0.543
48
5.15
0.543
54
5.67
0.800
60
6.45
0.800
2.1.11.3
Profile Wall PE Pipe
ASTM F 894, RSC 160, produced from PE certified by the resin producer as
meeting the requirements of ASTM D 3350, minimum cell class 334433C. Pipe
walls shall have the following properties:
Minimum Moment
Of Inertia of
Wall Section
(mm to the 4th/mm)
___________________
Nominal
Minimum
Cell
Cell
Size
Wall Area
Class
Class
(mm)
(square mm/m)
334433C
335434C
_______________________________________________________
450
6300
850
620
525
8800
1150
840
600
9900
1330
970
675
12500
2050
1490
750
12500
2050
1490
825
14800
2640
2160
900
17100
3310
2700
1050
16500
4540
3720
1200
18700
5540
4540
Minimum Moment
Of Inertia of
Wall Section
(in to the 4th/in)
___________________
Nominal
Minimum
Cell
Cell
Size
Wall Area
Class
Class
(in.)
(square in/ft)
334433C
335434C
_______________________________________________________
18
2.96
0.052
0.038
21
4.15
0.070
0.051
24
4.66
0.081
0.059
SECTION 02630
Page 22