with Department of Transportation regulations. All cylinders including but
not limited to fire extinguishers, spheres, or canisters containing an ODS
shall have a tag with the following information:
a.
Activity name and unit identification code
b.
Activity point of contact and phone number
c.
Type of ODS and pounds of ODS contained
d.
Date of shipment
e.
Naval stock number (for information, call (804) 279-4525).
3.3.5.2
Fire Suppression Containers
Fire suppression system cylinders and canisters with electrical charges or
initiators shall be deactivated prior to shipment. Also, safety caps shall
be used to cover exposed actuation mechanisms and discharge ports on these
special cylinders.
3.3.6
Transportation Guidance
Shipment of all ODS containers shall be in accordance with MIL-STD-129, DLA
4145.25 (also referenced one of the following: Army Regulation 700-68,
Naval Supply Instruction 4440.128C, Marine Corps Order 10330.2C, and Air
Force Regulation 67-12), 49 CFR 173.301, and DOD 4000.25-1-M.
3.3.7
Unsalvageable Material
Concrete, masonry, and other noncombustible material, except concrete
permitted to remain in place, shall be disposed of in the disposal area
located [_____]. The fill in the disposal area must remain below elevation
[_____] and after disposal is completed, the disposal area shall be
uniformly graded to drain. Dispose of combustible material [in the
sanitary fill area located [_____]] [off the site] [by burning].
3.4
CLEANUP
Debris and rubbish shall be removed from basement and similar excavations.
Debris shall be removed and transported in a manner that prevents spillage
on streets or adjacent areas. Apply local regulations regarding hauling
and disposal.
3.5
DISPOSAL OF REMOVED MATERIALS
3.5.1
Sub Title
Dispose of debris, rubbish, scrap, and other nonsalvageable materials
resulting rom removal operations with all applicable federal, state and
local regulations as contractually specified [off the [_____] center]
[_____]. Removed materials shall not be stored on the project site.
3.5.2
[Burning of materials removed from demolished structures will not be
from demolished structures to the areas designated for burning. Control
fires for protection of persons and property. Monitor fires continuously
SECTION 02220
Page 22