water: [_____] degrees C F, Ambient compressor room temperature:
[_____] degrees C F, Barometric pressure: [_____] kPa (absolute)
psia
b.
Winter design conditions:
Inlet air: [_____] degrees C F dry bulb and [_____] degrees C F wet
water: [_____] degrees C F, Ambient compressor room temperature:
[_____] degrees C F, Barometric pressure: [_____] kPa (absolute)
psia.
2.3.3.3
Critical Speeds
API Std 618, paragraph 2.5.1.
2.3.4
Electrical Service Conditions
2.3.4.1
Air Compressor Drive Motor
[_____] Volts, 3 phase, 3 wire, 60 hertz electrical service.
2.3.4.2
Accessory electrical Service
**************************************************************************
NOTE: Change accessory voltages if required for
site conditions.
**************************************************************************
See Table I.
TABLE I - COMPRESSOR ACCESSORY ELECTRICAL SERVICE SCHEDULE
Item
Voltage
Phase
Control Power and
120
1
60 Hz
Motors under 3/8 kW
Accessory Power
460
3
60 Hz
TABLE I - COMPRESSOR ACCESSORY ELECTRICAL SERVICE SCHEDULE
Item
Voltage
Phase
Control Power and
120
1
60 Hz
Motors under 1/2 hp
Accessory Power
460
3
60 Hz
2.3.5
Compressor Controls
Provide additional electrical, electro-pneumatic, or solid state electronic
controls for other specified control and monitor functions. All electrical
controls shall conform to NEMA ICS 2 as selected by the compressor
Controls shall be suitable for individual operation of the compressor or
parallel operation with one or more other compressors.
SECTION 15214N
Page 15