1.11.3
Shop Assembly Drawings
fabricated components in the shop to ensure satisfactory field installation.
1.11.4
Hydraulic Schematic
Hydraulic Schematic: A complete hydraulic schematic in accordance with
the schematic, and all setpoint and size parameters shall be indicated for
each component.
1.11.5
Delivery Drawings
Delivery drawings shall provide descriptions of methods of delivering
components to the site, including details for supporting fabricated
components during shipping to prevent distortion or other damage.
1.11.6
Field Installation Procedures
Field installation drawings shall provide a detailed description of the
field installation procedures. The description shall include the location
provisions to be taken to protect concrete and other work during
installation, the method of maintaining components in correct alignment,
and the methods for installing other appurtenant items.
PART 2
PRODUCTS
2.1
MATERIALS AND MECHANICAL EQUIPMENT
**************************************************************************
NOTE: The contents of the following paragraphs are
necessitate revision or expansion to cover different
conditions and standards.
**************************************************************************
2.1.1
General
Materials and mechanical equipment shall conform to the requirements
indicated or specified, and if not specified, then materials and mechanical
equipment of the best commercial grade quality suited to the intended use
and as approved shall be furnished. The manufacturer's name, address, and
catalog number shall be permanently displayed on a nameplate securely
attached to each major item of equipment.
2.1.2
Standard Products
Where items are referred to hereinafter as "similar and equal to" a
particular manufacturer's product, such references have been made merely as
a convenient method of indicating the type of material or equipment
required, with no intention of asserting superiority thereof. The standard
product of any reputable manufacturer regularly engaged in the commercial
will not be excluded on the basis of minor differences, provided essential
requirements of the specifications relative to materials, capacity, and
performance are met. The Contractor shall, in accordance with paragraph
SUBMITTALS, furnish for approval, performance capacities and other
SECTION 15010A
Page 15