Display/Indicator
Function
minutes after ac primary power is restored
e.
Keyboard shall contain control switches with the functions noted:
Control
Function
ON/PROGRAM
Lockswitch
Select mode of operation:
ON
Normal monitor and control operation
PROGRAM
User entry, installation-related data
10-key numeric number switchpad:
ON mode
Zone number entry to zone display
PROGRAM
Enter installation-related numeric data to
zone display
CLEAR DISPLAY
number entry
ACCESS
Change status of displayed zone from ALARM
or SECURE to ACCESS
SECURE
Change status of displayed zone from ALARM
or ACCESS to SECURE
RECALL
Display zone in numeric order within each
failure, ALARM, ACCESS
ACKN
Acknowledge alarm annunciation
ENTER PROGRAM
Transfer installation-related numeric
data displayed in zone display to memory
STATUS
With zone number displayed, print current
zone status for zone displayed. With zone
number display blank, print zone in numeric
order within each status group in status
PAPER
Advance printer paper
SYS TEST
Initiate 10-second central alarm reporting
and display unit test when zone number is not
displayed; initiate sensor self-test when zone
number is displayed; and [for RF system
test,] initiate sensor test and verify system
response as described in paragraph entitled
"RF Link Supervision"
LISTEN
Cause annunciation of analog, audio
SECTION 13703N
Page 64