3.1.1.6
Eye Wash Station
Where eyes may be exposed to injurious corrosive materials, suitable
facilities for quick drenching or flushing of the eyes shall be provided
within the work area.
3.1.1.7
Mechanical Ventilation System
a. Use adequate ventilation to control personnel exposure to lead in
accordance with 29 CFR 1926.62.
b. To the extent feasible, use local exhaust ventilation connected to
HEPA filters or other collection systems, approved by the CP. Local
exhaust ventilation systems shall be evaluated and maintained in
accordance with 29 CFR 1926.62.
c. Vent local exhaust outside the building only and away from building
ventilation intakes.
d. Use locally exhausted, power actuated, paint removal tools.
3.1.1.8
Personnel Protection
herein. Eating, smoking, or drinking or application of cosmetics is not
permitted in the lead control area. No one will be permitted in the lead
control area unless they have been appropriately trained and provided with
protective equipment.
3.2
ERECTION
3.2.1
Lead Control Area Requirements
**************************************************************************
NOTE: Choose the first paragraph if LBP will be
removed by means which will not likely create
airborne, lead-containing dust (such as careful wet
scraping or chemical stripping). Choose the second
paragraph if removal/control practice will create
airborne, lead-containing dust (such as sanding,
needle gun use).
**************************************************************************
[ Establish a lead control area by situating critical barriers and physical
boundaries around the area or structure where LBP/PWL removal/control
operations will be performed.]
**************************************************************************
NOTE: The Designer should consider the use of
square meters 1,000 square feet to save inspection
time.
**************************************************************************
[ Full containment - Contain removal operations by the use of [critical
barriers] [and HEPA filtered exhaust] [a negative pressure enclosure system
with decontamination facilities and with HEPA filtered exhaust if required
by the CP]. For containment areas larger than 100 square meters 1,000
SECTION 13283N