TABLE 3
NI0SH METHOD 7400
PCM ENVIRONMENTAL AIR SAMPLING PROTOCOL (NON-PERSONAL)
__________________________________________________________________
Sample
Minimum
Filter Pore
Min. Vol.
Sampling
Location
No. of
Size (Note 1)
(Note 2)
Rate
Samples
(Liters)
(liters/min.)
___________________________________________________________________
Inside
0.5/140
0.45 microns
3850
2-16
Abatement
Square
Area
Meters
(Notes
3 & 4)
___________________________________________________________________
Each Room in
0.45 microns
3850
2-16
1 Abatement
Area Less
than 140
Square meters
___________________________________________________________________
Field Blank
2
0.45 microns
0
0
___________________________________________________________________
Laboratory
1
0.45 microns
0
0
Blank
___________________________________________________________________
Notes:
1.
Type of filter is Mixed Cellulose Ester.
2.
Ensure detection limit for PCM analysis is established at
0.005 fibers/cc.
3.
One sample shall be added for each additional 140 square meters.
(The corresponding I-P units are 5/1500 square feet).
4.
A minimum of 5 samples are to be taken per abatement area,
plus 2 field blanks.
SECTION 13280A
Page 57